Multisolar 15kW: Optimise your solar energy production
MultiSolar: Store the bare minimum in your batteries and feed it back into the grid, provided the batteries are full.
Conversely, use the grid to make up for the shortfall in winter production, and top up the batteries when it rains.
Optimize your production to the maximum and never worry about a power cut again.
Connect up to 14850Wp to the PV input of the inverterb Hybrid
Store and use your solar-generated electricity at a later date.
Description
High-performance three-phase MultiSolar inverter for hybrid power systems.
Connect solar panels, batteries and, optionally, a mains input to power your system.
Enjoy top performance thanks to two independent integrated mppt trackers, as well as user-friendliness thanks to its compact design and intuitive LCD display.
- Pure sine wave output signal: 10kW
- Max PV input power: 14850Wp
- AC input: 3-phase
- AC output: 3-phase
- Microprocessor-controlled for greater stability
- Multiple operations:
- Grid-connected, off-grid and grid-connected with back-up power
- Integrated mppt solair charger (two independent inputs)
- Backlit LCD display for easy, interactive operation
- Multiple means of communication
- "Green" alternative to generators
- User-adjustable battery charging current, up to 200A
Remote control and UPS configuration
Connect the UPS to your computer using the USB cable supplied.
SolarPower software enables control and monitoring of multiple devices via LAN, Internet or USB.
Alert notifications, pop-up screen, sms and email.
Software
SolarPower 1.17SP7
Features
Phase |
phase in / 3 phase out |
Nominal DC voltage / Max. DC voltage |
720 |
|
DC / 900 VDC |
Starting voltage / Min. working voltage | 320 VDC / 350 VDC |
MPP voltage range | 400 VDC - 800 VDC |
Number of MPP inputs / max. input current |
: 37.65A ; B:18. |
6
Rated output voltage | 230 VAC (P-N)/400 VAC (P-P) |
Output voltage range | 184 - 264.5 VAC per phase |
Rated output current | 21.7 A per phase |
Maximum conversion efficiency (DC/AC) | 96.00% |
European voltage efficiency | 95,00% |
AC starting voltage / automatic restart voltage | 120 - 140 VAC per phase 180 VAC per phase |
Input voltage range | 170 - 280 VAC per phase |
Max. AC input current. | 40 |
A |
MPP voltage range | 350 VDC - 850 VDC |
Number of MPP inputs/max. input current |
: 37.65A; B:18.6A |
Nominal output voltage | 230 VAC (P-N)/400 VAC (P-P) |
DC voltage nominal / DC voltage max. | 720 |
VDC / 900 VDC |
Starting voltage / Min. working voltage | 320 VDC / 350 VDC |
MPP voltage range | 350 VDC - 850 VDC |
Number of MPP inputs / max. input current |
: 37.65A ; B:18.6A |
Rated output voltage | 230 VAC (P-N)/400 VAC (P-P) |
MPP voltage range | 184 - 264.5 VAC per phase |
Rated output current | 21, |
A per phase |
Starting voltage/Minimum working voltage | 120 - 140 VAC per phase 180 VAC per phase |
Input voltage range | 170 - 280 VAC per phase |
Nominal output voltage | 230 VAC (P-N)/400 VAC (P-P) |
Max. charging current |
Default 60A, |
|
5
Dimensions P x W x H | 219 x 650 x 820 mm |
Communication port | RS-232 / USB and CAN Interface |
Intelligent Slot | SNMP, |
Modbus and AS-400 cards available as options |
Environment |
- 90% RH (non-condensing) |
Working temperature |
- 1000 m |